STH-S81-5015 Langevin Transducer for Plastic Welding
Ultrasonic Transducers
General Application
High Power Ultrasonic (ex. ultrasonic welding)
Specifications
Tests environmental conditions: 23 ± 3 °C; 40 ~ 70% RH
Parameter | Specification | Remarks | |
---|---|---|---|
Resonant Fequency | fr | 15 ± 1 kHz | HP-4194 Impedance Analyzer at 1Vrms |
Resonance Resistance | Ro | < 12 ohm | HP-4194 Impedance Analyzer at 1Vrms |
Static Capacitance | Cp | 10.2nF ± 10% | LCR meter at 1kHz, 1Vrms |
Bandwidth | > 0.5 kHz | ||
Insulation Resistance | > 2000 Mohm | ||
Max. Input Power | 700 W | ||
Max. Voltage | Vin | 3000 Vpk-pk | |
Length | L | 165.4 mm | |
Weight | 1250 grams | ||
Joint Bolt | M18 x 1.5 |
How to order
If you need a specific quote, please request so by sending us an e-mail through "Request for Quote" by refering to the following part number or by calling us at 814-861-5688 (8:30am to 5:30pm EST). You can also directly place an order by calling us with your credit card information or sending us a Purchase Order form.
Purchasing Options
Article | Part Number | Price unit |
---|---|---|
Bolt Clamped Langevin Ultrasonic Transducer |
STH-S81-5015 |
1-9: $185.00 10-99: $140.00 100-499: $115.00 |